Velleman VMB1TCW Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Zubehör für elektrische Velleman VMB1TCW herunter. Velleman VMB1TCW User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Velbus system

VVVMMMBBB111TTTCCCWWW Temperature control module for the Velbus system

Seite 2

EMBEDDING A TEMPERATURE CONTROLLER TOGETHER WITH A SENSOR The controller (VMB1TC) can be embedded together with a sensor (VMB1TS) in a 4-module wid

Seite 3

OVERVIEW HEATING INSTALLATION A heating installation usually consists of radiators or convectors, a boiler, circulation pump and a collector with v

Seite 4 - CHARACTERISTICS

CONNECTION To interconnect the Velbus modules the use of twisted-pair cable (EIB 2x2x0.8mm2, UTP 8x0.51mm - CAT5 or equivalent) is recommended. Con

Seite 5

Relay cabinet wiring

Seite 6 - VELBUS CHARACTERISTICS

Terminator Normally only 2 ‘TERM’ terminators must be used in a complete Velbus installation. Usually this will be on the end of 2 bus wires (for

Seite 7

SCREEN INDICATIONS LED INDICATION Remark: When a menu is active, de LED indication is replaced with flashing LEDs on the ↑ and ↓ buttons tha

Seite 8

BUTTON FUNCTIONS Location Change room or zone. Push and hold to switch between rooms and zones.  Exit the menu. Changes made in a

Seite 9

MENU STRUCTURE Direct access menu  Open the menu by pressing the ‘Menu’ button.  Scroll through the menu with the ↑ or ↓ button. Sleep ti

Seite 10

Extended menu To change the program, settings or statistics of the different sensors or to change the configuration of the temperature controller,

Seite 11

 Scroll through the menu using the ↑ and ↓ buttons. Program Settings Operating mode Button lock Sleep timer Low temp. alarm High temp. ala

Seite 12 - CONNECTION

CONTENTS CONTENTS ...

Seite 13 - Relay cabinet wiring

CONFIGURATION OF THE TEMPERATURE CONTROLLER Choice of language The menu text can be displayed in different languages. Factory default is English,

Seite 14 - Allocate the relay channels

Temperature read-out (°Celsius or °Fahrenheit) Default setting for the temperature read-out is degrees Celsius. Change the setting to see the read-

Seite 15 - Mo 14:23 23

Master clock When your Velbus installation contains multiple modules with built-in clock (temperature controllers VMB1TC and control panel VMB4PD)

Seite 16

Global alarm This setting only applies when multiple temperature controllers are connected to your Velbus installation. Default the global alarm fu

Seite 17 - Direct access menu

Battery backup To avoid losing the clock when a power failure occurs, a backup battery (3V Lithium CR2032) can be installed in the battery holder a

Seite 18 - Extended menu

5. Select the battery backup menu with the → button. 6. Enable the battery backup watchdog when a battery is inserted or disable it when no batt

Seite 19

Searching for temperature sensors Before the controller can work together with the temperature sensors VMB1TS it must first scan the network for al

Seite 20 - Choice of language

Setting the clock This module works together with one or more temperature sensoresVMB1TS to form a programmable thermostat. It is important to set

Seite 21

9. Confirm with the → button to start the clock from the set time. 10. Exit the menu with the  button. Setting the alarm clock The mo

Seite 22 - Master clock

5. Confirm with the → button. The hour-indication of the wake-up time flashes. 6. Set the hour of the wake-up time with the ↑ or ↓ button. 7.

Seite 23 - Global alarm

VERIFY SOFTWARE VERSION ... 55 PIN CODE PROTECT

Seite 24 - Battery backup

12. Set the minutes of the go-to-bed time with the ↑ or ↓ button. 13. Confirm with the → button. 14. Exit the menu with the  or ← button. T

Seite 25

4. Disable the alarm clock function with the ↑ or ↓ button. 5. Confirm with the → button. 6. Exit the menu with the  or ← button. The

Seite 26

5. Change the contrast with the ↑ or ↓ button. 6. Confirm with the → button. 7. Exit the menu with the  button. Set

Seite 27 - Setting the clock

5. Select the backlight menu with the → button. 6. Change the hour of the first time frame with the ↑ or ↓ button and confirm with the → button

Seite 28 - Setting the alarm clock

Assign sensor names Default all the temperature sensors will have the same name (‘Temp sensor xx’). To distinguish between the different temperatu

Seite 29

7. Repeat step 6 until all characters are entered. 8. Exit the menu with the  button. 9. Press the ‘Location’ button to select the next s

Seite 30

5. Scroll through the sensor settings menu using the ↑ or ↓ button until the ‘Zone number’ item appears 6. Select the zone number menu with the

Seite 31 - Setting the display contrast

10. Repeat steps 1 through 9 for every sensor that needs to be added to a zone. Change the default zone names De names ‘Zone 1’, ‘Zo

Seite 32

5. Scroll through the sensor settings menu using the ↑ or ↓ button until the ‘Change name’ item appears. 6. Select the change name menu with

Seite 33

10. Press the ‘Location’ button to select the next zone. 11. Repeat steps 2 through 10 until every zone has a meaningful name. Hea

Seite 34 - Assign sensor names

DESCRIPTION The temperature controller (VMB1TC) forms in combination with one or more temperature sensors (VMB1TS) and relay modules (VMB1RY or VMB

Seite 35 - Defining zones

5. Select the operating mode menu with the → button. 6. Change the mode to heating or cooling using the ↑ or ↓ button. 7. Confirm with the

Seite 36

Lock or unlock local mode setting It is possible to switch between comfort, day, and night or anti-freeze mode locally on every temperature sensor

Seite 37

Default duration of temporary mode (default sleep time) The thermostat program can be temporary ignored by using the sleep timer. The default durat

Seite 38

Low temperature alarm The sensor can trigger an alarm when the temperature drops below a defined value. This could be useful when the heating syst

Seite 39 - Heating or cooling mode

High temperature alarm The sensor can trigger an alarm when the temperature rises above a defined value. This could be useful when a valve fails t

Seite 40

Anti-freeze temperature This is the lowest allowed room temperature. When temperature reaches or drops below freezing temperature, the heating wil

Seite 41

Heating limit This is the maximum desired room temperature that can be set. Default it is set to 30° but the user can change this limit. This coul

Seite 42

Minimum cooling temperature This is the minimum desired room temperature that can be set for the air conditioner. Default it is set to 16° but the

Seite 43 - Low temperature alarm

Maximum cooling temperature This is the highest allowed room temperature. When temperature rises above the maximum cooling temperature, the air c

Seite 44 - High temperature alarm

Hysteresis temperature Hysteresis defines the difference between the on- and off temperature of the heating or air-conditioning. 1. Press the ‘

Seite 45 - Anti-freeze temperature

Programming  A program instruction can switch a sensor between comfort, day, night or anti-freeze mode at a certain time.  Possibility to enter p

Seite 46 - Heating limit

Temperature difference Convectors often have a built-in fan for faster heating. This setting determines how much the temperature needs to drop bel

Seite 47 - Minimum cooling temperature

Difference sensor Using two sensors a differential thermostat can be created. When the difference in temperature between both sensors reaches a ce

Seite 48 - Maximum cooling temperature

Protecting the circulation pump When a circulation pump is not being used for some time, it might get stuck. To avoid this, an unjamming function

Seite 49 - Hysteresis temperature

Protecting the valves To avoid valves getting stuck, an unjam function is available. This function will open the valves for at least one minute ev

Seite 50 - Temperature difference

Calibrating the sensor When the read temperature does not match the real measured value on a thermometer, the read temperature can be corrected

Seite 51 - Difference sensor

VERIFY SOFTWARE VERSION Verify whether the controller contains the latest firmware by examining the firmware version. If the Velbus installation c

Seite 52

PIN CODE PROTECT THE EXTENDED MENU Default any user can access the extended menu. To avoid unauthorized users making changes in the extended menu,

Seite 53 - Protecting the valves

9. Change the last number of the PIN code with the ↑ or ↓ button and confirm with the → button. 10. Exit the menu with the  button. When

Seite 54 - Calibrating the sensor

OPERATING THE TEMPERATURE SENSOR VMB1TS Anti-freeze, night, day or comfort mode indication In rooms that have a temperature sensor VMB1TS the hea

Seite 55

Operation Pushing the push button repeatedly will switch the module between anti-freeze, night, day or comfort mode successively. When

Seite 56

VELBUS CHARACTERISTICS  2-wire communication for Velbus data and 2 wires for power supply  data transmission: 16.6 Kbit/s  Serial data protoc

Seite 57 - Change PIN code

OPERATING THE TEMPERATURE CONTROLLER VMB1TC Select room or zone To set up a heating system for different rooms, each room will need a temperatu

Seite 58

Recall and change the desired temperature At any time the desired temperature for a room can be shown and/or changed. 1. Press the ↑ or ↓ button

Seite 59 - Operation

When a room is selected on the controller the heating (or cooling) mode can be adjusted. When a zone is selected on the controller the heating (or c

Seite 60 - Select room or zone

Setting the sleep time (temporary mode) Once the heating (or air-conditioning) is in temporary mode, the duration of the sleep timer can be increa

Seite 61

Holiday setting When going on a holiday trip, the heating should be set to anti-freeze or night mode and a sleep timer should be configured. As lo

Seite 62 - - , , or ) is displayed

VMB1TC Temperature controller manual – rev 3.0 65 Summer setting During summer time the heating should be set in anti-freeze mode. All program i

Seite 63

Setting the comfort, day and night temperature The temperature sensor VMB1TS can be used in 4 modes (comfort , day , night or standby -). Ever

Seite 64

9. Set the desired day temperature with the ↑ or ↓ button. 10. Confirm with the → button. 11. Scroll to the night item with the ↑ button. 1

Seite 65

STATISTICS For every temperature sensor the minimum and maximum temperatures can be recalled as well as the time during which the heating or air-

Seite 66

7. Press the ↑ button. The first time indication shows how long the heating or AC was on during night mode. The second time indication shows how l

Seite 67

 reset the minimum and/or maximum temperature  reset the time statistics of a sensor  set or reset the de-blocking of the valve and/or circulation

Seite 68 - Requesting statistics

Reset statistics Statistics registration can be reset individually. 1. Press the ‘Location’ button repeatedly until the desired room of which

Seite 69

PROGRAM INSTRUCTIONS LOCATION This chapter is only applicable when multiple temperature controllers are connected to your Velbus installation. It

Seite 70 - Reset statistics

9. Confirm with the → button. The living room program instructions will only be stored on this controller. Remark: If on another controller the

Seite 71

PROGRAMMING The controller can handle up to 32 temperature sensors VMB1TS. Every room that needs to be heated or cooled must have its own tempera

Seite 72 - Local program

 When no sensor program is available, but there is a zone program, a ‘z‘ will appear on the display behind the mode symbol.  When no senso

Seite 73

Overview program instruction Location  ↑↓Menu→Mode ← Living room Mo-Su 22:30 Program mode - Anti-freeze Night Day Comfort Program

Seite 74

Entering a new program instruction 1. Press the ‘Location’ button repeatedly until the room or zone of which a program instruction needs to be a

Seite 75 - 22:30

9. Set the minutes using the ↑ or ↓ button and confirm with the → button. 10. Set the mode (comfort, day, night or anti-freeze mode) wi

Seite 76

Changing a program instruction 1. Press the ‘Location’ button repeatedly until the room or zone of which the program instruction needs to be cha

Seite 77 - Mo-Fr 6:45

9. Set the mode (comfort, day, night or anti-freeze mode) with the ↑ or ↓ button and confirm with the →button. The flashing cursor disappears.

Seite 78

EMBEDDING THE TEMPERATURE CONTROLLER It is also possible to use a 3-module wide frame with cover plate from the BTicino Living series. The module m

Seite 79 - Mo-Fr -30m

Removing a program instruction 1. Press the ‘Location’ button repeatedly until the room or zone of which the program instruction needs to be cha

Seite 80

DIFFERENTIAL THERMOSTAT Using two sensors, a differential thermostat can be created. When the temperature difference between both sensors crosses

Seite 81

The passage automatically 3° cooler than the office When the sensor module in the office is set to day-mode, the temperature in the passage must

Seite 82 - Office Passage

Set the difference sensor and difference temperature on the office sensor via the temperature controller 1. Press the ‘Location’ button until

Seite 83

9. Scroll through the sensor settings menu using the ↑ or ↓ button until the ‘Temp difference‘ item appears. 10. Select the temp. difference i

Seite 84

Passive cooling of a bedroom During summer time the bedroom is cooled via a fan that extracts air from a cooler room. Mount a temperature sensor

Seite 85 - Passive cooling of a bedroom

Set the difference sensor and difference temperature on the sensor of the cooler room via the temperature controller 1. Press the ‘Location’ bu

Seite 86

9. Scroll through the sensor settings menu using the ↑ or ↓ button until the ‘Temp difference‘ item appears. 10. Select the temp. difference it

Seite 87

Set the sensor of the bedroom to cooling mode via the temperature controller 14. Press the ‘Location’ button until ‘Bedroom’ is displayed 15

Seite 88

Set the sensor of the bedroom to comfort, day or night mode via the temperature controller This can be done via the pushbutton on the bedroom se

Seite 89 - 1h 0m *25

EMBEDDING A TEMPERATURE SENSOR The temperature sensor VMB1TS / VMB1TSW can be embedded in combination with a blank frame VMBFBI and a cover plate f

Seite 90

Refer to our website for more information: www.velbus.be

Kommentare zu diesen Handbüchern

Keine Kommentare