WLS552 PEREL
Clean the dipstick and insert it into the tank. Check the oil level if necessary. Make sure the oil level is between the
two marks on the dipstick.
Re-install the seal. Be careful not to damage the threads of the aluminium oil tank cover. Dispose of the oil according
to the local regulations.
• Transporting the Log Splitter
Unplug the log splitter from the mains and let it cool down. Move the log splitter using the handle. If it has to be
transported over long distances, make sure to install the log splitter on a flat and non-slippery surface. Fasten the log
splitter if necessary. Recommended transportation temperature: -25°C ~ +40°C.
5. Troubleshooting
Problem Cause Possible Solution
Incorrect positioning of the log Position log correctly
Log exceeds permitted dimensions Pre-cut log to meet dimensions
Wedge does not cut Sharpen wedge
Oil leak Locate oil leak, contact your dealer
Log fails to split
Hydraulic pressure too low Check oil level and refill if necessary
Log pusher advances with jerks or
strong vibrations
Air in hydraulic pump Make sure the bleed screw has been
loosened
Oil leaks Leakage from the tank Worn seals, contact your dealer
6. Technical Specifications
Electrical Motor
Voltage 240VAC/50Hz
Protection Class IP54
Power 1.5 kW
Rotation Speed 2,850 RPM
Splitter Data
Max. Length of Travel 375mm
Max. Splitting Force 5t
Oil Tank Capacity 3.7l
Splitter Capacity
Max. Diameter 250mm
Min. Diameter 50mm
Max. Length 520mm