4. Procedure
Inspection conditions
Viewing distance is approximately 35 ~ 40 cm (for
inspecting adjacent dots and distance between defect
dots, this distance is much closer)
Viewing angle is normal to the LCD panel (max. 10°
deviation)
Ambient temperature is 25 ± 5°C
Ambient humidity is 60 ± 5% RH
Ambient illuminance is between 300 ~ 500 Lux.
Input signal timing should be typical value.
A eye position
B LCD panel
Inspection criteria
Refer to the definitions in §2.
N = number of defects.
defect type limit
visual
defect
scratch
0.03mm W 0.1mm
L 10mm
N 4
defect
round 0.3mm Ø 1.0mm N 5
linear
W 1.0mm
L 3.0mm
N 5
polarizer 0.3mm Ø 1.0mm N 5
total allowed N 10
electrical
defect
single dot
bright* N 6
dark N 6
total allowed N 9
adjacent dots 2** 3 pairs
3** 2 sets
4** 1 sets
distance between 2 bright dots 10mm
line defects N = 0 (not allowed!)
*: visible through a 5% ND (Neutral Density) filter
**: adjacent dots also add to the single dot counter
Note: other defects that may occur e.g. mura are subject to user interpretation and should be
evaluated individually.