DVM345DI GB
2
2.3. Maintenance
• Always disconnect the test leads from all current sources before opening the meter.
• Replace blown fuses with an identical one or a fuse with identical voltage and current ratings
(15A/250V).
• Do not use the device and have it checked by qualified personnel if anomalies are observed
or in case of malfunction.
• Use a damp cloth and a mild detergent to clean the device. Never apply abrasives or
solvents to the meter.
3. DESCRIPTION
This device is a professional auto-ranging measuring instrument. All measured values are
displayed on a 3 ¾ digit LCD. The device is equipped with a 38-segment bar graph and can be
used to measure DC & AC voltages (both auto-ranging), DC & AC current, temperature,
resistance (auto-ranging) and capacitance. The user can also test diodes, transistors and
audible continuity.
3.1. "ON/OFF"-push button
Used to turn the device ON or OFF. The beeper sounds when this button is pushed.
3.2. DC/AC-RU -button
8VHGWRVHOHFW'&RU$&YROWDJHUDQJH'&RU$&FXUUHQWUDQJH RU range. The beeper
sounds when this button is pushed.
3.3. "R-H" button
Press this button to switch to manual operation when the device is in the auto-ranging mode. "R-H"
will be displayed. Hold the button for more than one second to return to the auto-ranging mode.
Push this button to change the voltage ranges as follows : 4V → 40V → 400V → 1000V.
3XVKWKLVEXWWRQWRFKDQJHWKHUHVLVWDQFHUDQJHVDVIROORZV0 →0 →N →N
→N →
3.4. "B/L"-button
Press this button to turn the back light ON or OFF.
3.5. Input Jacks
This meter has 4 input jacks with overload protection. Connect the black test lead to the "COM"-
jack and the red test lead to the following input jacks :
Function Red Lead Connection Input Limit
VDC/VAC 9 1000VDC or 750Vrms AC
9 250VDC or 250Vrms AC
9 250VDC or 250Vrms AC
mA mA 400mA DC or rms AC
10A 10A 10A DC or rms AC
Kommentare zu diesen Handbüchern