DVM870 Rev. 01
04.02.2010 ©Velleman nv
8
Range Resolution
Range Resolution Range Resolution
200µA 0.1µA 20mA 10µA 10A 10mA
2mA 1µV 200mA 100µA
RESISTANCE
Connect the red test lead to the "VmA" jack [9] and the black test lead
to the "COM" jack [7] (the red lead has a positive polarity "+").
Set the rotary switch [3] in the "" range position.
Connect the test leads to the resistor to be measured and read the LCD
display.
If the resistance being measured is connected to a circuit, turn off the
power and discharge all capacitors before applying the test probes.
Note:
wait a few seconds for a stable reading when measuring resistors >
1M.
Range Resolution
Range Resolution Range Resolution
200 0.1 20K 10 2M 1k
2k 1 200k 100 20M 10k
DIODE TEST AND AUDIBLE CONTINUITY TEST
Connect the red test lead to "VmA" jack [9] and the black one to the
"COM" jack [7] (the red lead has a positive polarity "+").
Set the rotary switch [6] in the position and use the select button
[3] to choose between diode or continuity test. Do not apply input
voltage at this setting!
For diode tests, connect the red test lead to the anode of the diode to be
tested and the black test lead to the cathode of the diode. The approx.
forward voltage drop of the diode will be displayed. If the connection is
reversed, the display will show “OL”.
For continuity tests, connect the test leads to two points of the circuit to
be tested. If continuity exists, the built-in buzzer will sound.
Notes:
forward DC current: ±0.5mA
backward DC voltage: ±1.5V
open circuit voltage: ±0.5V
buzzer sounds when resistance < 50
TEMPERATURE
Set the rotary switch [6] in the °C/°F position and use the select button
[3] to choose between °C and °F. Do not apply input voltage at this
setting!
Insert the cathode (black pin) in the "COM" jack [7], and the anode (red
pin) in the "VmA" jack [9].
Use the other end of the thermocouple to measure temperatures.