9. Technische specificaties
This device is not calibrated when purchased!
Regulations concerning environment of use:
• Use this meter only for measurements in CATI, CATII, CAT III (<1000V) and CAT
IV (<600V) environments (see §4)
• Use this meter only in a pollution degree 2 environment (see §5)
Ideal working conditions include:
• Temperature: 18 to 28°C (64°F to 82°F)
• relative humidity: max. 75%
• altitude: max. 2000m (6560ft)
9.1. General
600V CAT IV, 1000V CAT III
3
5/6-
digit LCD, 2 to 3 samples/sec.
Fuse Protection
µA/mA-range: 630mA/1000V (Ø10.3x38mm)
10A-range: 10A/1000V (Ø10.3x38mm)
0.1x(specified accuracy)/°C (<18°C or >28°C)
9V alkaline battery 6LR61
"OL" is displayed automatically
Battery-Low Indicat ion
Operating Temperature
0°C to 40°C (32~122°F) (<80%RH, <10°C non
condensing)
-10°C to 60°C (14~140°F) (<70%RH, battery removed)
9.2. DC Voltage
±(0.5% of rdg + 5 digits)
±(0.8% of rdg + 5 digits)
Input Impedance: >10MΩ for all ranges
9.3. AC Voltage
±(1.0% of rdg + 5 digits)
Input Impedance: >10MΩ for all ranges
Frequency Range: 40 to 400Hz
Overload protection: 1000Vdc or ac rms.
9.4. DC Current
±(1.5% of rdg + 3 digits)